Distal Radius Extra-articular T-Locking Plate

Distal Radius Extra-articular T-Locking Plate-I features a four-hole distal head, compact T-shaped design and pure titanium construction for stable extra-articular distal radius fracture fixation.

Product Name Distal Radius Extra-articular T-Locking Plate
Brand Davin Med
Product Type Orthopedic Locking Plate
Applicable Region Distal Radius
Application Extra-articular Distal Radius Fracture Fixation
Material TA3G Pure Titanium
Surface Treatment Anodized
Product Code KZ011-1542 Series
Distal Head 4 Holes
Configuration Left / Right
Specification 3/4/5/6/7 Holes
Length 49/58/67/76/85 mm
Compatible Screws Ø2.4/2.7 mm Locking Screws, Ø2.7 mm Cortical Screws
OEM/ODM Available

Davin Med · Orthopedic Trauma

Distal Radius Extra-articular T-Locking Plate-I

Davin Med Distal Radius Extra-articular T-Locking Plate-I is designed for internal fixation of extra-articular distal radius fractures. Its four-hole distal head provides subchondral support, while the longitudinal shaft supports axial stability.

Manufactured from anodized TA3G pure titanium, the plate is available in left and right configurations, with 3–7 holes and lengths of 49–85 mm.

Compatible with 2.4/2.7 mm locking screws and 2.7 mm cortical screws. Select the configuration according to fracture anatomy and approved product instructions.

Distal Radius Extra-articular T-Locking Plate-I with compatible locking and cortical screws
Distal Radius Extra-articular T-Locking Plate-I with compatible locking and cortical screws

Product Design

Six Key Advantages of Distal Radius Extra-articular T-Locking Plate-I

The compact T-shaped plate combines four-point distal support with a straightforward shaft design.

01

Four-point Distal Support

Four distal screw holes provide targeted subchondral support.

02

Extra-articular Fixation Design

The screw layout is designed to minimize the risk of intra-articular screw penetration.

03

Compact Plate Profile

The simplified geometry is intended to limit soft tissue exposure and tendon contact.

04

Efficient Surgical Handling

The straightforward T-shaped structure supports streamlined screw placement.

05

Pure Titanium Construction

Anodized TA3G pure titanium offers favorable corrosion resistance and biocompatibility.

06

Multiple Size Options

Five lengths are available for each side to accommodate different anatomical requirements.

Distal Radius Extra-articular T-Locking Plate-I product details
Distal Radius Extra-articular T-Locking Plate-I product details

Implant Specifications

Distal Radius Extra-articular T-Locking Plate-I Design and Applications

The four-hole distal head and longitudinal shaft provide complementary support for extra-articular fracture fixation.

  • Material: TA3G pure titanium, anodized.
  • Product series: KZ011-1542, left and right.
  • Hole options: 3–7 holes.
  • Length: 49–85 mm.
  • Compatible screws: 2.4/2.7 mm locking screws and 2.7 mm cortical screws.

Listed applications include AO A2 simple metaphyseal fractures, AO A3 comminuted metaphyseal fractures with an intact articular surface, and extra-articular fractures with mild angulation requiring correction, where soft tissue conditions permit open reduction.

Specification Note: Confirm approved indications, packaging and sterilization status before ordering.

Product Size & Coding

Distal Radius Extra-articular T-Locking Plate-I Complete Size Chart

The tables below list all ten left and right configurations. Catalog hole counts refer to the size options, separately from the four-hole distal head.

Distal Radius Extra-articular T-Locking Plate-I product reference
Distal Radius Extra-articular T-Locking Plate-I product reference
Distal Radius Extra-articular T-Locking Plate-I
Product No.SideHolesLength (mm)
KZ011-1542L030Left349
KZ011-1542L040Left458
KZ011-1542L050Left567
KZ011-1542L060Left676
KZ011-1542L070Left785
KZ011-1542R030Right349
KZ011-1542R040Right458
KZ011-1542R050Right567
KZ011-1542R060Right676
KZ011-1542R070Right785
Material and Compatibility
ParameterDetails
MaterialTA3G Pure Titanium
Surface TreatmentAnodized
Compatible Screws2.4/2.7 mm locking screws and 2.7 mm cortical screws
Packaging / SterilizationConfirm before ordering

Product List Note: Select the correct side, size and compatible instruments before ordering.

Technical Specifications

Distal Radius Extra-articular T-Locking Plate-I Technical Specifications

The following summary presents the KZ011-1542 plate series.

Distal Radius Extra-articular T-Locking Plate-I Specification Summary
SpecificationKZ011-1542Ordering Consideration
Product CodeKZ011-1542Refer to size chart
ConfigurationLeft / RightConfirm side
MaterialTA3G Pure TitaniumAnodized surface
Holes3–7Select hole count
Length49–85 mmRefer to size chart
Locking Screws2.4/2.7 mmConfirm size
Cortical Screws2.7 mmConfirm size
ApplicationExtra-articular distal radius fracture fixationConfirm approved indications
01 / PLATE MODEL

Four-hole T-Locking Plate

The four-hole distal head provides subchondral support.

02 / SIZE OPTIONS

Left and Right Sizes

Five lengths are available for each side.

03 / COMPATIBLE SCREWS

Compatible Screw System

Compatible with 2.4/2.7 mm locking screws and 2.7 mm cortical screws.

Specifications follow the Davin Med Trauma catalog. Confirm model-specific details before ordering.

Distributor & OEM Enquiries

Distal Radius Extra-articular T-Locking Plate-I for Orthopedic Distributors

Davin Med offers extra-articular distal radius fixation plates for orthopedic medical device distributors.

01 / PRODUCT SELECTION

Plate Size Selection

Choose the required side, hole count and plate length.

02 / PRODUCT IDENTIFICATION

Model Identification

Use KZ011-1542 catalog codes to confirm the configuration.

03 / OEM & ODM SUPPORT

Orthopedic Trauma Solutions

Contact Davin Med to discuss OEM/ODM, labeling and packaging requirements.

Product Questions

Frequently Asked Questions About Distal Radius Extra-articular T-Locking Plate-I

Explore extra-articular distal radius fracture fixation, four-hole head design and implant specifications.

1. What is a distal radius extra-articular T-locking plate?

It is an orthopedic locking plate designed for extra-articular distal radius fractures. The T-shaped head provides distal support through four screw holes, while the longitudinal shaft supports axial stability.

2. Which fractures can the four-hole T-locking plate address?

The product literature lists AO A2 simple metaphyseal fractures and AO A3 comminuted metaphyseal fractures with an intact articular surface, as well as selected extra-articular fractures requiring correction of angulation.

3. Why does the distal head have four holes?

The four-hole head provides four potential points of subchondral support without additional wings or branches. The compact design is intended for extra-articular fracture patterns where broader articular fragment coverage is not required.

4. What is an extra-articular distal radius fracture?

An extra-articular distal radius fracture occurs near the wrist without extending into the articular surface. The fixation strategy depends on fracture morphology, displacement, bone quality and the approved indications of the implant.

5. How does the T-shaped locking plate provide stability?

The transverse head supports the distal fragment while the longitudinal shaft supports axial alignment. Locking screws engage the plate to form a fixed-angle construct when used according to the approved instructions.

6. How does an extra-articular T-locking plate differ from a dual-column plate?

The four-hole T-locking plate has a simpler distal head intended for extra-articular fixation. A dual-column plate may provide broader fragment coverage where required by fracture morphology. The designs are not automatically interchangeable.

7. How does the extra-articular screw layout address joint penetration risk?

The distal screw layout is intended to avoid unnecessary extension into the joint region. Appropriate screw length and placement remain essential, and the design does not eliminate the possibility of joint penetration.

8. What material is used in the extra-articular T-locking plate?

The plate uses TA3G pure titanium with an anodized surface. The product literature identifies corrosion resistance and intraoperative recognition as intended benefits of the surface treatment.

9. Which screws are compatible with the KZ011-1542 series?

The Davin Med Trauma catalog specifies 2.4/2.7 mm locking screws and 2.7 mm cortical screws. Screw length and compatibility should be confirmed against the selected model and approved product instructions.

10. Why are left and right plate configurations available?

Separate left and right configurations accommodate the anatomy of each distal radius. Each side is available in five catalog hole counts, from three to seven, for different fixation requirements.

11. What lengths are available for the KZ011-1542 plate?

The catalog lists 49, 58, 67, 76 and 85 mm lengths corresponding to three through seven catalog holes. Each length is available in separate left and right configurations.

12. What factors influence plate selection for AO A2 and A3 distal radius fractures?

Relevant factors include metaphyseal comminution, angulation, bone quality, soft tissue conditions and the required fixation length. Implant selection should follow the fracture morphology and approved product instructions.

Request a Quotation for Davin Med Distal Radius Extra-articular T-Locking Plate-I

Looking for distal radius locking plates? Contact Davin Med for product information and quotation support.

Please include product number, side, size, quantity and destination country.

Discuss orthopedic trauma distribution, technical documentation and OEM/ODM requirements with Davin Med.

解释
Distributor Support

More Than Product Supply

Practical support for orthopedic distributors, importers and medical buyers worldwide.

  • 01
    Product Matching

    Product selection and system configuration.

  • 02
    Fast Quotation

    Quick pricing and product confirmation.

  • 03
    Catalog Support

    Catalogs, specifications and product images.

  • 04
    Documentation

    Certificates and registration documents.

  • 05
    OEM / ODM Service

    Custom products, packaging and branding.

  • 06
    Complete System Supply

    Implants, instruments and containers.

You May Also Like

Talk to Davin med orthopedic experts

We offer a full range of quality spine, trauma, joint, and sports medicine products - fastdelivery, consistent quality.

Comprehensive Portfolio

Orthopedic implants and instruments for human and veterinary applications.

Focus on Quality

Precision manufacturing and quality inspection across key production stages.

Global Partnership

Working with distributors, importers and OEM partners worldwide.

Dedicated Support

Product selection, technical documentation and order support at every step.