PGR Complete Instrument Set
PGR Complete Instrument Set is designed for veterinary patellar groove reconstruction and patellar luxation treatment with complete implants and surgical instruments for canine orthopedic surgery.
| Model | PGR Complete Instrument Set |
| Brand | Davinmed |
| Applicable Region | Canine Knee Joint / Patellar Groove |
| Application | Veterinary Patellar Groove Reconstruction and Patellar Luxation Treatment |
| Material | Medical-Grade Titanium Alloy and Surgical Instrument Materials |
| MOQ | 1 Set |
| Dispatch Time | Within 10 Days for Standard Products |
| Certifications | CE, ISO 13485 |
| OEM/ODM Services | Custom implants, laser marking, instrument configurations and packaging |
| Clinical Support | Surgical technique guides, operation videos and veterinary technical support |
| Customization Lead Time | Within 15 Days, Excluding Shipping Time |
| Shipping Methods | FedEx, DHL, TNT, EMS, and Other International Couriers |
Davin Med · Veterinary Orthopedics
PGR Complete Instrument Set
The Davin Med PGR Complete Instrument Set is designed for veterinary surgical patellar groove reconstruction in the knee, supporting controlled implant delivery and stable tissue fixation.
Its minimally invasive workflow supports fracture fixation surgery through standard portals while helping manage implant placement, tissue approximation and fracture stabilization with a compact repair device.
For orthopedic distributors, medical device importers and hospital procurement teams, product selection should confirm the repair technique, device configuration, implant option, accessory instruments and packaging requirements.
Product Design
PGR Complete Instrument Set Design & Veterinary Surgical Workflow
Stable Fracture Fixation
The intramedullary nail system supports controlled delivery to the repair site, helping position the repair construct during veterinary surgical patellar groove reconstruction.
Minimally Invasive Surgical Approach
A compact delivery configuration is designed for use in fracture fixation surgery, supporting access to the patella through minimally invasive veterinary surgical portals.
Fracture-Based Configuration
Select the device, implant configuration and required accessories according to the intended patellar repair technique and approved product instructions.
Component Matching
Patellar Implant Device & Repair Components
The PGR nail system and its compatible implant or repair components should be selected as a matched system. Confirm the required configuration before ordering for veterinary surgical patellar groove reconstruction.
- Confirm the PGR nail system model and delivery configuration.
- Verify the compatible implant or repair implant option.
- Specify any required veterinary surgical accessories and instruments.
- Confirm sterile status, packaging and supplied components for the selected reference.
Similar appearance does not establish interchangeability. Use only documented device, implant and repair component combinations specified for the selected system.
Technical Specifications
PGR Complete Instrument Set Configuration
Use the configuration checklist below when requesting a PGR complete instrument set quotation. Confirm the selected intramedullary fixation technique, device format, implant option and supply condition before ordering.
| Specification Item | Configuration to Confirm | Procurement Notes |
|---|---|---|
| Repair Technique | Veterinary Surgical PGR Complete Instrument Set | Confirm all-inside or other required repair workflow |
| Target Anatomy | Canine Knee Joint / Patellar Groove | Confirm intended repair location and clinical indication |
| Device Format | Proximal Femoral Intramedullary Nail | Confirm delivery and handle configuration |
| Implant Configuration | Compatible Locking Screw and Blade Component | Confirm implant profile, material and quantity |
| Repair Implant | PGR Blade and Locking Components | Confirm implant type and supplied configuration |
| Instrument Compatibility | PGR Surgical Instruments | Confirm passer, grasper, cutter or knot-pushing requirements |
| Supply Condition | Product-Reference Specific | Confirm sterile status, packaging, shelf life and IFU |
Materials, implant configurations and supplied components may vary by product reference. Confirm the current specification, packaging and availability before placing an order.
System Configuration
Selection for Proximal Femoral Fracture Fixation
A PGR complete instrument set combines the repair device with compatible implants, repair components and veterinary surgical instruments to support a controlled fracture fixation surgery workflow.
Product selection should be based on the intended patella repair technique and the approved instructions for use. Indications, device configuration and accessory requirements should be confirmed for the selected product reference.
| Selection Item | Required Information |
|---|---|
| PGR Complete Instrument Set Device | Product reference, delivery configuration, intended repair technique and device format. |
| Implant / Repair Component | Compatible implant or implant configuration, material, profile and quantity for the selected system. |
| Accessory Instruments | Required passer, grasper, cutter, knot pusher or other veterinary surgical patellar repair instruments. |
| Supply Condition | Sterile or non-sterile status, packaging, labelling and applicable instructions for use. |
| Documentation | Product specification and applicable conformity documents for the ordered reference and destination. |
Distributor & OEM Enquiries
Request a Product-Specific Quotation
Send your PGR complete instrument set requirements so the selected repair configuration, quantities, compatible components and veterinary surgical instrument needs can be reviewed together.
Define Your Repair Configuration
Specify the patellar repair technique, device model, implant configuration and quantity required for each product reference.
Specify the Supply Scope
State whether you require the repair device only, compatible implants or implants, accessories or a complete patella repair instrument set.
Include Market Requirements
Provide the destination country, documentation requirements and any OEM marking or private-label packaging requests for review.
Related Instrumentation
Instrumentation for PGR Complete Instrument Set Procedures
Match the Repair System with Compatible Instruments
A compatible patellar groove reconstruction instrument set should be selected according to the intramedullary fixation technique, device interfaces and the approved surgical workflow.
When requesting a PGR complete instrument set, include your fracture fixation surgery instrument requirements so implant handling, tissue access, cutting and repair interfaces can be checked before order confirmation.
- Request the current patellar repair instrument list and tray configuration.
- Confirm compatibility with the selected repair device and implant system.
- Specify a complete set or individual replacement instruments.
- Request the applicable cleaning, sterilization and maintenance instructions.
| Instrument Group | Compatibility to Confirm |
|---|---|
| Patellar Access Instruments | Veterinary Surgical access and tissue preparation instruments required for the selected patellar groove reconstruction technique. |
| Implant Passing Instruments | Implant passer or delivery interface compatible with the selected PGR complete instrument set. |
| Implant Management Instruments | Graspers and retrieval tools required for controlled implant handling during fracture fixation surgery. |
| Cutting / Knot Instruments | Compatible implant cutter, knot pusher or related finishing instruments where required by the technique. |
| Instrument Tray | Set contents, identification layout and applicable reprocessing instructions. |
This checklist identifies configuration requirements, not a confirmed packing list. Request the itemized instrument list, quantities and compatible repair references with your quotation.
Product Questions
FAQ About the PGR Complete Instrument Set
What is a PGR complete instrument set used for?
A PGR complete instrument set is designed to support veterinary surgical repair of selected patellar injuries by delivering compatible implants or repair components for tissue approximation and fixation.
Is this system designed for orthopedic trauma surgery?
The system is intended for veterinary surgical patellar groove reconstruction workflows in the knee. Confirm the approved indications and surgical technique for the selected product reference before use.
What does all-inside patellar repair mean?
All-inside patellar repair refers to a technique in which the repair construct is delivered and secured from within the joint using an veterinary surgical device. Availability depends on the selected system.
Does every PGR nail system use the same implant configuration?
No. Implant profiles, repair implants and delivery mechanisms may differ by product reference. Confirm the compatible configuration and supplied components before ordering.
Can different implants or repair implants be interchanged?
Use only implants and repair components documented as compatible with the selected intramedullary nail system. Similar appearance does not establish interchangeability.
Which instruments should be ordered with the PGR complete instrument set?
Instrument requirements depend on the repair technique. Confirm whether implant passers, graspers, cutters, knot pushers or a complete patellar groove reconstruction instrument set are required.
Is the matching instrument set included in the product quotation?
Specify whether the enquiry is for the repair device only or for a complete veterinary surgical patellar repair solution. Confirm itemized contents and pricing scope in the quotation.
Can the system be used for different patellar tear patterns?
Suitability depends on the selected product, repair technique and approved indications. Confirm the applicable instructions for use rather than assuming one configuration covers every tear pattern.
How can buyers confirm material and sterile supply status?
Request the material specification, packaging label and applicable instructions for the ordered reference. Confirm sterile status, shelf life and packaging before purchase.
What information is required for a distributor or OEM quotation?
Provide the patellar repair configuration, quantity, destination country and required accessories or instruments. Include any marking, packaging or documentation requirements for review.
Discuss Your PGR Complete Instrument Set Requirements
Request a quotation for the PGR Complete Instrument Set and compatible veterinary surgical instruments or repair components.
Please include: repair configuration, quantity, implant or implant requirements, instrument requirements and destination country.
Submit your specification list through the product enquiry form on this page.
More Than Product Supply
Practical support for orthopedic distributors, importers and medical buyers worldwide.
-
01Product Matching
Product selection and system configuration.
-
02Fast Quotation
Quick pricing and product confirmation.
-
03Catalog Support
Catalogs, specifications and product images.
-
04Documentation
Certificates and registration documents.
-
05OEM / ODM Service
Custom products, packaging and branding.
-
06Complete System Supply
Implants, instruments and containers.
For distributors and professional medical buyers.
Talk to Davin med orthopedic experts
Comprehensive Portfolio
Orthopedic implants and instruments for human and veterinary applications.
Focus on Quality
Precision manufacturing and quality inspection across key production stages.
Global Partnership
Working with distributors, importers and OEM partners worldwide.
Dedicated Support
Product selection, technical documentation and order support at every step.